Metra Performance validation summary

October 2026

Preliminary results from our own testing. These results are not peer reviewed. A peer-reviewed study is in preparation, and the numbers may change as the app is updated.

We validated Metra against force plates, the gold standard for vertical jump testing.

23athletes
1.2–4.0%*relative error (RMSE) across 16 measures
0.97–0.99agreement with the force plates (ICC), all 18 measures

* Excludes dynamic rebound index (DRI): 6.6% on the drop jump and 7.9% on the hop test. DRI's error is two to three times contact time's: contact time is squared, and on the hop test the previous hop's height adds its own error in the same direction. Its ICC is in the range shown.

Methods

  • ParticipantsN = 23.
  • PhoneiPhone 14 Plus on a tripod, front-on to the athlete at 6 ft (1.83 m), with the lens 18 in (45.7 cm) above the force plates and the phone level. No markers and no calibration.
  • Force platesVALD ForceDecks dual force plates sampling at 1000 Hz, recording the same jumps at the same time.
  • ProtocolAll tests with hands on hips, in this order: countermovement jump (stand still for 2–3 s, then one continuous dip and jump); hop test (10 continuous hops after one warm-up hop); drop jump (step off a box 16 in (40.6 cm) above the force plates, land, and jump straight back up).
  • AnalysisEach jump recorded by Metra was paired with the same jump on the force plates.
  • Exclusions
    • Two or more consecutive dropped video frames during the jump: 5 of 450 jumps (1 countermovement jump, 4 drop jumps), left out of every measure.
    • Landing partly off the force plates: 6 of 116 countermovement jumps, 49 of 229 hops and 4 of 105 drop jumps, left out of the measures that use that landing or contact.
    • No still stance before and after the jump: 22 of 115 countermovement jumps, left out of the measures compared with the Owen et al. (2014) method.
    This is why the number of jumps differs between measures.

How the force plate values were obtained

Timing measures

Flight time, contact time, contraction time and the RSI values built from them were measured from the force trace using the force plate software's own event definitions.

Measures from integrating the force trace

Jump height from take-off velocity, countermovement depth, mean propulsive force and mean landing force come from integrating the force trace to get the velocity and position of the centre of mass. These values depend on two things: the athlete's body weight, and the instant the integration starts. If it starts after the athlete has already begun to move, for example after a small rise before the dip, the error carries through the whole calculation. Owen et al. noted that around half of jumpers start a countermovement jump this way.

The Owen et al. (2014) method

We compared these measures with this published criterion method, applied to the raw force trace of every jump:

  1. Body weight is the average force over 1 s of still standing before the jump.
  2. The jump starts at the first point where force moves more than 5 standard deviations away from body weight, in either direction, so a small rise is caught as well as the dip.
  3. Integration begins 30 ms before that point.

Results

Measure Jumps Relative error (RMSE) Absolute error (RMSE) 95% limits of agreement ICC
Countermovement jump · 23 athletes
Flight time1091.2%6.6 ms−13.2 to +12.90.99
Jump height, flight time1092.4%0.9 cm−1.8 to +1.80.99
Jump height, take-off velocity *932.4%1.0 cm−2.0 to +1.70.98
Contraction time1152.4%19.4 ms−37.0 to +39.00.98
Countermovement depth *933.8%1.4 cm−2.9 to +2.70.97
RSI-modified1093.5%0.02 m/s−0.04 to +0.030.99
Mean propulsive force *931.6%0.03 ×BW−0.07 to +0.060.98
Mean landing force *932.9%0.08 ×BW−0.17 to +0.140.99
Hop test · 22 athletes
Flight time1801.7%6.3 ms−12.2 to +12.40.99
Contact time1802.7%5.7 ms−11.3 to +11.10.99
Jump height1803.4%0.6 cm−1.2 to +1.20.99
RSI1594.0%0.07−0.14 to +0.150.98
DRI †1257.9%0.08−0.14 to +0.160.98
Drop jump · 21 athletes
Flight time971.4%7.3 ms−14.7 to +14.30.99
Contact time1012.9%7.4 ms−15.1 to +13.70.99
Jump height972.8%0.9 cm−1.9 to +1.80.99
RSI973.9%0.08−0.17 to +0.160.98
DRI †976.6%0.09−0.18 to +0.180.98

* Compared with the Owen et al. (2014) method.
† DRI = (drop height + jump height) / (g × contact time²). Drop jump: the box height. Hop test: the previous hop's jump height. DRI's error is two to three times contact time's: contact time is squared, and on the hop test the previous hop's height adds its own error in the same direction.

Relative error (RMSE)
The root-mean-square of each jump's difference from the force plate, as a percentage of the force plate's value.
Absolute error (RMSE)
The root-mean-square difference from the force plate, in the measure's own units.
95% limits of agreement
The range that the difference between the app and the force plate falls within for 95% of jumps (Bland–Altman), app minus force plate. Same units as the absolute error.
ICC
Intraclass correlation for absolute agreement, ICC(2,1). 1 means the app and the force plates agree exactly.

Supported iPhones

Metra runs on iPhone 13 and newer. The “e” models, such as iPhone 16e, are not supported.

Reference: Owen NJ, Watkins J, Kilduff LP, Bevan HR, Bennett MA (2014). Development of a criterion method to determine peak mechanical power output in a countermovement jump. Journal of Strength and Conditioning Research 28(6): 1552–1558.
Preliminary summary. Not peer reviewed. Updated October 2026.